Streaming at 700kbps,
640*480, 05:19
We believe that you can understand the iPRECIO® well easily by watching this video.
If you have any inconvenience to watch the streaming, please let us know by using contact form.We will send you the video by DVD media.
Using the easy to use menu driven iPRECIO software, header information along with infusion protocol details are entered and ultimately downloaded to the pump's flash memory. Start Time, End Time, Flow-rate (1.0µl/hour to 30.0µl/hour), Constant and Variable infusion mode are programmable. Both Constant and Variable infusion options have Instant or Recovery Mode Infusion settings.
In Variable infusion mode, 10 flow-rate steps are user programmable. Further sophistication may be obtained by using iPRECIO's Repeat Mode where the 10 steps are programmed within one or several repeat cycle loops (5 loops maximum). Each loop may be repeated 2-250 times.*
The programmable feature will make iPRECIO pumps indispensable for applications where accurate flow infusion, recovery/washout periods, constant/variable dose or complex circadian infusion studies are necessary.
*subject to battery life
1. Instant Infusion :
Start infusion of the drug instantly by pre-programmed protocol following activation of the pump drive.

![]() |
|
2. Post Recovery (Delayed) Infusion :
Start Infusion of the drug after reservoir contents are exchanged percutaneously following recovery period from implantation surgery by pre-programmed protocol. The pump infuse saline or buffer during the recovery period.

![]() |
|
1. Constant Flow Rate :
Configure one constant flow rate for infusion

![]() |
|
||
|
2. Variable Flow Rate :
Configure up to 10 discrete infusion "steps" between 1μL/hr to 30μL/hr

![]() |
|
||
|
Repeat Mode :
Repeat Mode allows the 10 flow steps to be used in a more sophisticated Infusion protocol where up to 2500* steps may be programmed. Therefore infusing protocols taking into account circadian rhythm, oral drug intake (3-4 times per day) or studies for dose response curves may be programmed.
* 10 steps x 250 times repeated (subject to battery life)

User can select each combination between the infusion mode and flow rate mode.
| Infusion Mode | Flow Rate Mode | Description | |
|---|---|---|---|
| 1 | Instant Infusion | Constant Flow Rate | The pump starts administration instantly at the pre-programmed start time & date and continues to infuse for the pre-programmed flow-rate and duration. |
| 2 | Instant Infusion | Variable Flow Rate | The pump starts administration instantly at the pre-programmed start time & date and continues to infuse at the various pre-programmed flow-rate steps and durations. |
| 3 | Post Recovery Infusion | Constant Flow Rate | The pump starts administration after the animals convalescence period following surgery. During the convalescence/recovery period saline is infused at a programmable constant flow-rate. On completion of the recovery period, the pump operates as described in instant constant flow-rate. |
| 4 | Post Recovery Infusion | Variable Flow Rate | The pump starts administration after the animals convalescence period following surgery. During the convalescence/recovery period saline is infused at a programmable constant flow-rate. On completion of the recovery period, the pump operates as described in instant variable flow-rate. |
| <Input General Information of the study> Study Name, Number/ ID, Date, Animal Species, Strain, Age, Compound Name/ID, Concentration, Buffer Name, Administration Route, Number of Groups and Animals, etc. |
|
| <Animal Groups Settings> # User inputs the concentration of solution and estimated maximum/minimum body weight expected of a subjected animal at the end of the study. Then the software automatically calculate the maximum/minimum dose which can be administered during the experiments. # User selects either “Infusion Mode” or “Flow Rate Mode” and inputs the dose or flow rate of solution which will be administered. ** User can select the software types of “20 Groups x 20 Animals” or “50 Groups x 50 Animals”. |
|
| <Advanced Settings of the Infusion/Flow Rate Modes> User program infusion protocol as infusion mode and flow rate mode for each animal/pump. Also user input Animal ID, Body Weight, Sex at this step. |
|
| <Download of the Protocol Settings to the each Pump> Check the infusion protocol and schedule set for each animal/pump and download its protocol into the memory installed inside of the pump. |
![]() |
![]() |
|
IR communications are used for loading the infusion program and activating the pump. It is made directly without removal from the blister pack. Therefore sterility is maintained until the pump is taken to the sterile surgical suite for filling/activation and implantation.

Each pump's unique ID and calibration factor is read from each pump during the programming phase.
For GLP compliance, accuracy of flow infusion can be validated.
In addition, the iPRECIO can be user calibrated.
User log-in and password control options are available to the study director to restrict access to iPRECIO Management Software.

We will exhibit the iPRECIOŽ at the Experimental Biology 2010 which will be held at the Anaheim Convention Center, Anaheim, CA on April 25 - 27, 2010. (Booth #117)
November 17, 2009
See Support Page for iPRECIOޑs Bibliography.
November 17, 2009
See How to buy / Distributor page.
February 1, 2010
iPRECIOŽ Luncheon seminar will be held at Hilton Hotel adjacent to Anaheim Convention Center during Experimental Biology 2010. Expect further announcements.
February 2, 2010